Concentrated Equipment Operation Procedures

Author:


  Extraction and concentration equipment is suitable for the pharmaceutical and food industries and can effectively extract substances such as medicinal juice and fruit juice. However, to ensure the normal use of the machine, it must be operated using the correct methods and procedures. Only in this way can the machine's optimal performance be guaranteed.
  
  1. Pre-start-up preparations: Check that all seals and valves on the equipment are intact and leak-free; check that the vacuum pump rotates flexibly and is in good condition; check that the electrical appliances and voltage in the control box are normal; check that the boiler is full of water; and check that the cooling circulation water is normal.
  
  2. Open the top cover of the extraction tank, weigh the materials according to the specified requirements and put them into the extraction tank, add the corresponding water or solvent, turn on the main power supply, turn on the automatic heating button, open the cooling water on the condenser, set the required temperature value on the temperature controller, start the hot water pump hot water circulation, and when the target temperature is reached, turn on the vacuum pump. Note: Before starting the vacuum pump, open the water inlet valve. Do not run the pump dry without water. Open the vacuum valve of the extraction tank and maintain the vacuum in the extraction tank at -0.03MPa to -0.04MPa to increase the boiling point and material dynamics in the tank. If the vacuum pump makes a screaming sound, slightly adjust the air leak valve on the vacuum pump head counterclockwise. After extraction, turn off the hot water pump circulation pump power supply and open the vent.
  
  3. Turn on the extraction heating start button. At this time, the extraction tank officially enters the working state. If stirring is required, start the stirring motor button and open the cooling water inlet valve so that the steam generated during extraction or concentration condenses into liquid water. When heating for extraction, the exhaust valve on the extraction tank must be opened, otherwise high pressure will be generated in the tank, which is dangerous.
  
  4. After extraction, turn off the extraction heating button and the stirring motor. Before concentration, open the vacuum pump inlet valve, then start the vacuum pump (starting the vacuum pump without water will damage the vacuum pump). When the vacuum reaches 0.05 MPa, open the material valve at the bottom of the extraction tank to draw the material into the concentration tank for concentration. Set the required concentration temperature on the concentration material table. After the material enters the concentration tank, observe the temperature displayed on the concentration material temperature gauge. If it is lower than the actual concentration temperature, start the concentration heating button and reset the concentration heating temperature for concentration.
  
  5. When the required concentration is reached, turn off the concentration heating system, then turn off the vacuum pump, then close the vacuum pump water inlet valve and the cooler water inlet valve. After concentration, first open the exhaust valve on the concentration tank, and release the material from the material valve. If it is gelatinous, open the side door and scoop it out with a spoon.
  
  6. After concentration, turn off the power, drain the slag, and clean.