How does the concentration equipment ensure its airtight seal?

Author:


  The extraction and concentration equipment is a combined unit for extraction and concentration, suitable for the extraction, concentration, paste making, percolation, volatile oil extraction, and alcohol recovery of heat-sensitive materials such as plants, animals, traditional Chinese medicine, and food additives, to meet the needs of higher education institutions, research institutions, and hospitals for new drug extraction, determination of new process technology parameters, intermediate experiments, new product development, extraction of valuable medicinal materials, and concentration of medicinal solutions.
  
  The entire production process is carried out under closed conditions, with a one-time operation, low solvent usage, and short time.
  
  The sealing mechanism of the extraction and concentration equipment includes a connecting frame, a sealing gasket, and a cylinder. The connecting frame is installed on the upper inner wall of the shell. Multiple fixing sleeves are evenly spaced on the lower end of the inner side of the connecting frame. A cylinder is provided at the upper end of each fixing sleeve. A limit plate is provided at the end of the cylinder. A sealing gasket is provided at the upper end of the limit plate. The sealing gasket corresponds to the recess.
  
  To ensure the sealing effect, attention should also be paid to the standardization of operation. First, check the sealing of the extraction slag discharge door; second, prevent the input of medicinal materials from damaging the liquid outlet filter. After adding the medicinal materials, close the feeding port, open the pure water valve or open the liquid outlet valve of the alcohol storage tank and the alcohol pump to add the solvent to the extraction tank. Simultaneously, open the steam valve of the extraction tank (observe the steam pressure through the pressure gauge, control the degree of valve opening to keep the steam pressure within the operating range), the condensate bypass valve. When the pressure is slightly stable, open the ball valves at the front and rear of the drain, and close the bypass valve. Open the cooling water valve of the condenser and observe the liquid flowing down from the oil-water separator. After adding the solvent, close the pure water valve or alcohol pump, and open the extraction stirring motor (if stirring is required). Open the extraction liquid outlet valve, extraction liquid outlet pump, and extraction liquid inlet valve to allow the extraction liquid to circulate automatically, accelerating the extraction speed. After the solvent in the extraction boils, adjust the steam valve, maintain a low heat to keep the liquid in the tank boiling for the required production time (generally 30 min, the time requirement varies depending on the medicinal materials, or no boiling is required), and simultaneously close the liquid outlet valve and liquid outlet pump.