14

2022

-

10

How to maintain extraction and concentration equipment

Author:


 

Extraction and concentration equipment is suitable for extracting and concentrating effective components from traditional Chinese medicine and various plants, and can achieve solvent recovery and essential oil collection. It is especially suitable for hospitals, pharmaceutical factories, and scientific research units to develop new products and conduct small-batch production. So, do you know how to maintain extraction and concentration equipment?
  1. To ensure work efficiency and product quality, it is necessary to keep the heating tube clean. When changing varieties or after several batches of production, use 4% sodium hydroxide to wash away the dirt inside the heating tube. The method is: Open the inlet valve and inject the alkaline solution, open the steam valve and add heat, soak for half an hour, and drain for later use. Use a steel brush to scrub the inner wall of the heating tube, rinse it with clean water, boil it in clean water for half an hour, and then rinse it with clean water again.
  2. Before starting the equipment, check the power supply, switch status, and water source of the equipment. Check whether all connecting parts are tightened and whether the valves are in the correct position.
  3. Pay attention to the level of heat transfer oil (water) in the sight glass of the extraction tank. Do not add too much to prevent overflow during heating. The heat transfer oil vent valve should be kept open during operation.
  4. Regularly check the sealing of each connection and the combined part of the tank, replace the sealing ring in time, and regularly check each valve for leakage.
  5. Check the cable connections monthly and pay attention to the heat dissipation of the electrical control cabinet.
  6. After use, rinse with cold water or soak with detergent, use a brush to remove dirt from the inside of the tank, the pipe wall, and the separator, and rinse with clean water.
  7. After starting the vacuum pump, observe the vacuum gauge to judge and analyze whether there is any air leakage in the concentrator unit. If necessary, use other effective methods to check the air leakage point or ask a professional to handle it.
  8. In case of damage to parts or water shortage during operation, the multi-functional extraction and concentration machine for traditional Chinese medicine should be stopped immediately, and the vacuum pump should be removed for repair.
 Hu Bei Ou Mei Qi Mechanical Equipment Manufacturing Co., Ltd.  Hope this helps!